ResourcesTroubleshooting GuidesEvaporator Coil Freezing Up
Troubleshooting Guides

Evaporator Coil Freezing Up

An iced evaporator coil restricts airflow entirely and can wash liquid refrigerant back to the compressor, leading to mechanical slugging.

Remediation Steps

  1. Turn off the cooling call immediately and run the fan on 'ON' to melt ice.
  2. Check for dirty filters, blocked return grills, or restricted capillary tubes.
  3. Measure system operating pressures once defrosted to verify refrigerant charge level.